3G3MX2-A2150-EV2 OMRON MX2 Inverter Drive VFD AC Motor Speed Controller

3G3MX2-A2150-EV2
Omron 3G3MX2 Drive
21.5A Variable Frequency Drive

3G3MX2-A2150-EV2

The Omron 3G3MX2-A2150-EV2 is a 21.5A variable frequency drive from the 3G3MX2 series, delivering precise motor speed control, energy efficiency, and robust performance for industrial automation, featuring compact design and reliable operation.

    SEODescription

    The **3G3MX2-A2150-EV2** is a compact and versatile **21.5A Variable Frequency Drive** from Omron's **3G3MX2 Drive** series, designed for precise motor control in industrial applications. It features a 3-phase 200-240V AC input and 3-phase 0-240V output, supporting direct connection to standard induction motors. The drive includes 2 analog inputs, 1 analog output, and 4 digital I/O ports for flexible integration with sensors, PLCs, or external control modules. It supports RS-485 communication via Modbus RTU protocol for network connectivity. Operating within a temperature range of -10°C to 40°C and 85% humidity (non-condensing), it is ideal for manufacturing, HVAC, and material handling systems. Key advantages include energy efficiency, user-friendly programming, and robust overload protection, though its limited support for advanced protocols like Ethernet/IP may restrict use in highly automated setups.

    SEOSpecification

    Parameter Specification
    Model 3G3MX2-A2150-EV2
    Product Series Omron 3G3MX2 Drive
    Rated Output Current 21.5A
    Drive Type Variable Frequency Drive (VFD)
    Input Voltage 3-phase 200-240V AC
    Output Power 11 kW (15 HP)
    Frequency Range 0.5-400 Hz
    Control Method V/F Control, Sensorless Vector
    Protection Rating IP20 (Enclosure)
    Overload Capacity 150% for 60 seconds

    SEOQandA

    question:Can I schedule official courier pickup myself?
    answer:Yes, you can arrange self-pickup with official couriers by providing necessary documentation.
    question:Does the company offer upgraded or alternative models?
    answer:We provide upgraded or alternative models based on availability; contact sales for options.
    question:Why can other suppliers source discontinued models you cannot?
    answer:Suppliers may have remaining stock or refurbished units, but quality risks may apply.

    SEOQandA_Product

    question:Motor doesn't start with 3G3MX2-A2150-EV2. What to check?
    answer:Verify input voltage (200-240V AC), ensure 'Run' command signal is active, and check frequency reference source settings in parameters.
    question:How to resolve E.OC1 overcurrent error during acceleration?
    answer:Increase acceleration time (C1-01), check motor cable for shorts, and confirm motor inertia matches load requirements.
    question:Why does 3G3MX2-A2150-EV2 show E.TH1 overheating alarm?
    answer:Clean air vents, ensure ambient temperature
    question:Analog speed control not working. How to troubleshoot?
    answer:Check 0-10V wiring (terminals A1/A2), set A001=01 for analog input, and verify no broken potentiometer if used.
    question:How to reset 3G3MX2-A2150-EV2 to factory defaults?
    answer:Set parameter A081=01, power cycle, then reconfigure motor-specific parameters (C1 group) for your application.