Leave Your Message
Products Categories
Featured Products

3G3MX2-A4007-P-E Omron MX2 Series Inverter Drive VFD AC Motor Controller

Omron 3G3MX2-A4007-P-E
MX2 7.5kW VFD
400V Inverter Drive

3G3MX2-A4007-P-E

Omron 3G3MX2-A4007-P-E MX2 7.5kW VFD: 400V inverter drive for industrial motor control, offering energy-efficient operation and compact design.

    SEODescription

    The Omron 3G3MX2-A4007-P-E is a robust MX2 7.5kW VFD designed for industrial motor control, offering a 400V Inverter Drive solution with three-phase input and output compatibility. It supports direct integration with external control modules, including analog/digital I/O expansion, and features built-in RS-485 communication for Modbus RTU protocol connectivity. Operating within a voltage range of 380-480V AC and a temperature range of -10°C to 50°C, it is ideal for applications in manufacturing, HVAC, and material handling. Key advantages include compact design, energy-saving algorithms, and user-friendly parameter configuration. However, its lack of built-in Ethernet or advanced fieldbus options may require additional hardware for complex automation systems. The drive excels in reliability and ease of installation but may need supplementary cooling in high-ambient environments.

    SEOSpecification

    Parameter Specification
    Model Omron 3G3MX2-A4007-P-E
    Rated Power MX2 7.5kW VFD
    Input Voltage 400V Inverter Drive (3-phase)
    Output Current 15A
    Frequency Range 0.5-400Hz
    Control Method V/f Control, Sensorless Vector
    Protection Features Overcurrent, Overvoltage, Motor Overload
    Ambient Temperature -10°C to +50°C (Operation)
    Enclosure Rating IP20

    SEOQandA

    question:Why is the shipping cost so high? Are there more economical shipping options?
    answer:Shipping costs vary by region and weight. We offer economy shipping options for cost-sensitive orders. Contact us for details.
    question:Why was the product label cut upon receipt?
    answer:Label removal is a standard procedure for customs clearance or carrier policies. Rest assured product quality remains unaffected.
    question:What shipping methods do you support?
    answer:We support DHL, Fedex, UPS, and other major carriers. Contact our team to choose the best option for your needs.

    SEOQandA_Product

    question:What causes an E.OC1 overcurrent error during acceleration?
    answer:Excessive load or short acceleration time. Adjust H3-09 (acceleration time) and verify motor load.
    question:How to resolve motor failure to start with 3G3MX2-A4007-P-E?
    answer:Check parameter settings (A1-02, b1-01). Ensure correct voltage (E1-01) and motor specs (E2-01).
    question:Why does communication with PLC fail via RS485?
    answer:Verify baud rate (C5-01) matches PLC settings. Check wiring integrity and terminal connections.
    question:How to address E.TH1 overtemperature alarm?
    answer:Clean air vents, confirm fan operation (monitor U2-14). Ensure ambient temperature
    question:How to reduce motor humming noise during operation?
    answer:Adjust carrier frequency (C6-02) between 2-15kHz. Higher values reduce noise but increase heat.