Leave Your Message
Products Categories
Featured Products

3G3MX2-A4022-P-E Variable Frequency Drive (VFD) | Omron MX2 Series Inverter

3G3MX2-A4022-P-E Drive
3G3MX2 400V Inverter
A4022-P-E VFD

3G3MX2-A4022-P-E

3G3MX2-A4022-P-E Drive, a 3G3MX2 400V Inverter and A4022-P-E VFD, provides precise motor speed control, energy-efficient operation, and robust performance for industrial automation applications.

    SEODescription

    The **3G3MX2-A4022-P-E Drive** is a compact 400V inverter designed for industrial motor control, featuring a 3-phase 400V AC input and output rated for 2.2 kW (3 HP) motor applications. As part of the **3G3MX2 400V Inverter** series, this **A4022-P-E VFD** supports direct integration with PLCs and external I/O modules via built-in digital/analog inputs (4 digital, 2 analog) and relay outputs, enabling flexible system configurations. It operates within a voltage range of 380–480V AC and a temperature range of -10°C to 50°C, suitable for harsh environments in industries like manufacturing, HVAC, and water treatment. Communication is enabled via RS-485 (Modbus RTU), though lacks advanced protocols like Ethernet. Key advantages include energy-efficient performance, user-friendly programming, and robust overload protection (150% for 60s), while limitations include basic networking capabilities and no built-in safety torque-off (STO). Ideal for mid-power applications requiring reliability and simplicity.

    SEOSpecification

    Parameter Specification
    Drive Model 3G3MX2-A4022-P-E Drive
    Input Voltage 3-phase 380-480V AC
    Output Power 2.2 kW
    Voltage Class 3G3MX2 400V Inverter
    Control Method Vector Control / V/F Control
    Frequency Range 0.5-400 Hz
    Protection Features Overcurrent, Overvoltage, Overheat, Short Circuit
    Communication Interface Modbus RTU (RS-485)
    Cooling Method Forced Air Cooling
    Environmental Rating IP20, -10°C to +40°C
    Application Type A4022-P-E VFD for Industrial Machinery

    SEOQandA

    question:Does the company have a professional product selection engineering team?
    answer:Yes, we have a dedicated team of engineers who exclusively focus on product research and optimization.
    question:Can I schedule self-pickup via official logistics partners?
    answer:Yes, clients can independently book self-pickup services through our partnered logistics providers.
    question:Do you offer technical specification support for product customization?
    answer:We provide full technical consultation and specification guidance tailored to your market needs.

    SEOQandA_Product

    question:Motor overload alarm triggers frequently with 3G3MX2-A4022-P-E
    answer:Check load exceeds 2.2kW rating, verify mechanical binding, adjust acceleration time (parameter C1-01/C1-02), and monitor thermal protection settings (L1-01).
    question:Drive displays 'OPR' error during operation
    answer:Confirm control mode selection (A1-02=0 for keypad), check run command source (A1-01=0 for terminal), and verify enable signal wiring integrity.
    question:RS485 communication failure with PLC interface
    answer:Validate baud rate alignment (C5-01), confirm station address (C5-02), check termination resistors, and ensure Modbus RTU protocol settings match master device.
    question:Inconsistent motor speed under sensorless vector control
    answer:Perform auto-tuning (T1-01=1), verify motor parameters (E1-01 to E1-06), ensure adequate load inertia, and check AVR function status (C6-02).
    question:DC bus overvoltage (OV) fault during deceleration
    answer:Extend decel time (C1-02), enable dynamic braking (L2-01=1), check braking resistor connection, and verify mains voltage stability within 200-240VAC range.