Leave Your Message
Products Categories
Featured Products

3G3MX2-AB007-P-E VFD Inverter Drive - Omron MX2 Series AC Motor Speed Controller

3G3MX2-AB007-P-E
3G3MX2-VFD
AB007-Inverter

3G3MX2-AB007-P-E

The 3G3MX2-AB007-P-E is a 3G3MX2-VFD series AB007-Inverter designed for industrial motor control, featuring compact design, high efficiency, and precise speed regulation in automation systems.

    SEODescription

    The **3G3MX2-AB007-P-E** is a compact variable frequency drive (VFD) from the **3G3MX2-VFD** series, designed for precise motor speed control in industrial automation. It features a 3-phase 200-240V AC input and output, supporting motors up to 0.75 kW (1 HP). The **AB007-Inverter** integrates 2 analog/digital inputs and 2 relay outputs for flexible control, while supporting direct connection to external braking resistors and optional communication modules like RS-485 (Modbus RTU). Operating within a temperature range of -10°C to 50°C and a voltage tolerance of ±10%, it is ideal for HVAC, pumps, conveyors, and machinery requiring energy-efficient performance. Key advantages include compact size, simplified parameter tuning, and overload protection, though it lacks advanced networking protocols like Ethernet/IP, limiting scalability in complex systems. Its rugged design ensures reliability in harsh environments but may require additional cooling in high-temperature applications.

    SEOSpecification

    Parameter Specification
    Model Number 3G3MX2-AB007-P-E
    Drive Series 3G3MX2-VFD
    Inverter Type AB007-Inverter
    Power Rating 0.75 kW (1.0 HP)
    Input Voltage 3-phase 200-240 VAC
    Output Current 3.6 A
    Control Method Sensorless Vector Control
    Protection Class IP20
    Communication RS-485 Modbus
    Cooling Method Fan-cooled

    SEOQandA

    question:Can we apply for low-value declaration for shipments?
    answer:Yes, if compliant with local regulations. Provide details for accurate assessment.
    question:Does the company offer technical selection services?
    answer:Yes, we provide technical guidance to help clients choose suitable products.
    question:Why is a service fee charged?
    answer:Service fees cover transaction processing, documentation, and administrative costs for transparency.

    SEOQandA_Product

    question:Why does the 3G3MX2-AB007-P-E display an 'OC' (Overcurrent) fault during startup?
    answer:Check motor wiring for shorts, ensure motor matches drive rating, and increase acceleration time (parameter n019) to reduce inrush current.
    question:How to resolve communication failure between 3G3MX2-AB007-P-E and PLC via Modbus RTU?
    answer:Verify baud rate (n151), parity (n152), and station number (n150) settings match PLC configuration. Check RS485 wiring polarity.
    question:Why does the drive show 'OH' (Overheat) alarm during operation?
    answer:Clean obstructed heatsinks, verify cooling fan operation (Fn-02 monitoring), and ensure ambient temperature stays below 40°C (104°F).
    question:How to fix inconsistent motor speed with 3G3MX2-AB007-P-E in V/F control mode?
    answer:Perform autotuning (n001=04), verify load isn't exceeding rated torque, and check for proper voltage input (3-phase imbalance
    question:Why does the drive trip immediately when enabling run command?
    answer:Inspect for phase-to-phase motor short circuits, validate input voltage (200-240V 1-phase), and check brake resistor wiring (if used) for faults.