6ES7221-3AD30-0XB0 Digital Input Module - Siemens SIMATIC S7-1200 SMART PLC DI Module

Siemens 6ES7221-3AD30-0XB0
S7-1200 Digital Input Module
PLC Digital Input 24V

6ES7221-3AD30-0XB0

The Siemens 6ES7221-3AD30-0XB0 is a S7-1200 Digital Input Module offering 24V PLC-compatible digital input channels for industrial automation control systems.

    SEODescription

    The Siemens 6ES7221-3AD30-0XB0 is a compact S7-200 Digital Input Module designed for PLC systems, offering 8 digital input channels to interface 24V DC sensors or switches. This PLC Digital Input 24V module supports direct connection to S7-200 CPUs via its integrated expansion interface, enabling seamless integration within automation setups. It operates within a voltage range of 20.4–28.8V DC and functions reliably in temperatures from 0°C to 55°C, making it suitable for industrial environments like manufacturing, packaging, and machinery control. The module features optical isolation for noise immunity and includes LED status indicators for real-time diagnostics. While its compact design and plug-and-play compatibility simplify installation, its limitation lies in compatibility exclusively with the S7-200 series, lacking support for advanced communication protocols like Profibus or Ethernet. Ideal for cost-effective, small-scale automation solutions.

    SEOSpecification

    Parameter Specification
    Manufacturer Siemens
    Model Number 6ES7221-3AD30-0XB0
    Module Type S7-1200 Digital Input Module
    Input Channels 16 digital inputs
    Input Voltage 24V DC (20.4-28.8V)
    Input Current 4mA typical per channel
    Isolation 500V AC between field & logic
    Response Time 0.1ms (ON), 4.5ms (OFF)
    Power Consumption 5W (from CPU bus)
    Connection Type Screw terminal block
    Operating Temp 0°C to 55°C
    Certifications CE, UL, cULus

    SEOQandA

    question:Do you provide technical selection services?
    answer:Yes, we offer expert technical selection services to ensure optimal solutions.
    question:Is post-delivery payment accepted?
    answer:No, we prioritize secure transactions but offer flexible terms for trusted partners.
    question:Why choose your company?
    answer:Asia's leading industrial automation trader with 20+ years, 85% repeat clients, and guaranteed quality.

    SEOQandA_Product

    question:Module not detected by PLC. What to check?
    answer:Verify DIP switch settings, ensure unique address, check power supply and wiring connections.
    question:Unstable analog input readings. Possible causes?
    answer:Check shielded cable grounding, isolate from EMI sources, ensure proper sensor wiring.
    question:Incorrect input type selected in software. How to resolve?
    answer:Confirm input type (voltage/current) in STEP 7-Micro/WIN matches sensor output configuration.
    question:Input signal exceeds module range. Solution?
    answer:Validate sensor output matches 0-10V/0-20mA range. Use signal conditioner if required.
    question:Module power LED off. Troubleshooting steps?
    answer:Verify 24VDC power supply polarity, check fuse integrity, ensure terminal block is secured.