Leave Your Message
Products Categories
Featured Products

6SL3210-1KE18-8AP1 Control Unit CU320-2DP SINAMICS S120 Drive Technology Motor Module

6SL3210-1KE18-8AP1
SINAMICS S120 Drive Module
18A Motor Controller

6SL3210-1KE18-8AP1

The 6SL3210-1KE18-8AP1 is a SINAMICS S120 Drive Module functioning as an 18A Motor Controller for precise motor control in industrial automation applications.

    SEODescription

    The **6SL3210-1KE18-8AP1** is a **SINAMICS S120 Drive Module** designed for industrial automation, offering precise control as an **18A Motor Controller**. It operates within a voltage range of **380–480V AC** (3-phase) and supports **47–63Hz** input frequency. This module integrates seamlessly with SINAMICS components, directly connecting to power and control units while supporting **PROFIBUS/PROFINET** interfaces for real-time communication. It features built-in safety functions (e.g., Safe Torque Off) and is optimized for high-performance applications in industries like **manufacturing, robotics, and heavy machinery**. Advantages include robust dynamic response, modular scalability, and energy efficiency. However, its complexity requires specialized setup tools and expertise. Operating temperatures range from **0°C to 40°C**, ensuring reliability in demanding environments.

    SEOSpecification

    Parameter Specification
    Product Code 6SL3210-1KE18-8AP1
    Device Type SINAMICS S120 Drive Module
    Rated Current 18A
    Input Voltage 3AC 380-480V ±10%
    Output Power 12kW (at 400V)
    Cooling Method Forced air cooling
    Communication Interface PROFIBUS/PROFINET optional
    Protection Class IP20
    Operating Temperature 0°C to +40°C
    Storage Temperature -40°C to +70°C
    Relative Humidity 5% to 95% (non-condensing)
    Weight Approx. 5.8kg

    SEOQandA

    question:Can you provide shipment photos and purchase dates for similar products?
    answer:Yes, we can provide relevant information upon request. Please specify the product details for accurate records.
    question:Can I schedule official courier pickup myself?
    answer:Yes, self-scheduled pickups are allowed. Please share your courier account and pickup details in advance for coordination.
    question:Why is shipping costly? Are there cheaper options?
    answer:Costs depend on weight and destination. We offer economical alternatives—contact us for tailored solutions.

    SEOQandA_Product

    question:What causes 'F0003' overcurrent fault on 6SL3210-1KE18-8AP1?
    answer:Check motor load, wiring insulation, and ensure acceleration time (P1120) isn't too short.
    question:Why does 6SL3210-1KE18-8AP1 show 'F0004' overtemperature alarm?
    answer:Verify cooling fan operation, clean air vents, and maintain ambient temperature below 40°C.
    question:How to resolve communication failure with PROFIBUS on 6SL3210-1KE18-8AP1?
    answer:Check DP connector termination, address settings (P918), and use shielded twisted-pair cables.
    question:Why does motor jerk during start with 6SL3210-1KE18-8AP1?
    answer:Optimize V/f curve (P1310-P1312), enable slip compensation (P1335), and check encoder alignment.
    question:How to reset 6SL3210-1KE18-8AP1 to factory settings?
    answer:Set P0010=30, P0970=1, wait until P0971 shows '1', then power cycle the drive.