Leave Your Message
Products Categories
Featured Products

FX2NC-96MT Mitsubishi FX2N Series PLC Controller, 96 I/O Compact Programmable Logic Module, Expansion Unit

Mitsubishi FX2NC PLC
FX2NC-96MT Expansion Module
96MT Transistor Output

FX2NC-96MT

The Mitsubishi FX2NC-96MT Expansion Module is a compact PLC extension unit designed for FX2NC series, featuring 96MT transistor outputs for high-speed control in industrial automation. Supports seamless integration with existing systems while delivering reliable performance in space-constrained applications.

    SEODescription

    The Mitsubishi FX2NC-96MT Expansion Module is a high-density I/O unit designed for the FX2NC PLC series, featuring 48 digital inputs and 48 transistor outputs (96MT Transistor Output) for precise control in automation systems. Compatible with up to 8 expansion modules, it supports RS-485/422 communication and operates on 24V DC within 0–55°C. Ideal for manufacturing and machinery, it offers compact design, high-speed switching (up to 100 kHz), and compatibility with servo/stepper drives. While its modularity enhances scalability, the FX2NC-96MT requires careful power management and lacks built-in analog I/O. Its robust performance suits applications demanding reliable discrete control in space-constrained environments.

    SEOSpecification

    Parameter Specification
    Model Series Mitsubishi FX2NC PLC Expansion Module
    I/O Configuration 96MT Transistor Output (64 inputs / 32 outputs)
    Power Supply 24V DC ±10%
    Output Type Sinking/Sourcing Transistor (0.5A per point)
    Processing Speed 0.08μs per basic instruction
    Program Memory 16k steps (EEPROM backup)
    Communication Ports RS-422/Programming port, expansion capability for CC-Link
    Operating Temperature 0°C to 55°C
    Mounting Method DIN rail or direct screw mounting
    Isolation Protection Photocoupler isolation for I/O circuits

    SEOQandA

    question:Can you provide shipment photos and purchase dates for similar products?
    answer:Yes, we can provide relevant shipment photos and purchase details upon request.
    question:Can the company offer upgraded or alternative models?
    answer:Yes, we offer upgraded and alternative models based on availability and client requirements.
    question:Is low-value declaration applicable for shipments?
    answer:Low-value declaration may apply for eligible shipments; confirm with local customs regulations first.

    SEOQandA_Product

    question:I/O points not responding during operation
    answer:Check wiring connections, ensure correct voltage supply, and verify PLC is in RUN mode. Test individual points using monitoring tools.
    question:Communication failure with programming software
    answer:Verify correct COM port settings, check cable integrity, and ensure drivers are installed. Restart software and PLC if needed.
    question:Unexpected PLC shutdown or reset
    answer:Inspect power supply stability (24VDC±10%), check for short circuits, and confirm backup battery voltage exceeds 3V if used.
    question:Program cannot be written to memory
    answer:Switch PLC to STOP mode, clear memory protection setting, and ensure compatible programming software version (e.g., GX Works2).
    question:Extension modules not recognized
    answer:Confirm proper module installation sequence, check connector alignment, and verify total I/O count doesn't exceed 256 points limit.