FX3U-4AD Mitsubishi MELSEC FX Series 4-Channel Analog Input Module PLC ADC

Mitsubishi FX3U-4AD
4CH analog input
12-bit resolution module

FX3U-4AD

Mitsubishi FX3U-4AD is a 4CH analog input module offering 12-bit resolution, designed for FX3U series PLCs to acquire precise voltage/current signals in industrial automation, process control, and data monitoring applications.

    SEODescription

    The **Mitsubishi FX3U-4AD** is a versatile 4CH analog input module designed for industrial automation systems, offering precise signal acquisition with its 12-bit resolution. This module supports up to four analog input channels, compatible with voltage (0–10V DC, -10–10V DC) or current (4–20mA) signals, enabling flexible integration into diverse control environments. It seamlessly connects to Mitsubishi FX3U/FX3UC PLCs, allowing direct expansion of up to eight special function modules. Operating within a 24V DC power supply and a temperature range of 0–55°C, it ensures reliability in harsh industrial settings such as manufacturing, process control, and machinery automation. Key advantages include high accuracy, easy configuration via programming software, and compact design. However, it lacks built-in isolation between channels and may require external signal conditioning for noise-prone environments.

    SEOSpecification

    Parameter Specification
    Model Mitsubishi FX3U-4AD
    Input Channels 4CH analog input (voltage/current)
    Resolution 12-bit resolution module (0-4095)
    Input Range DC 0-10V, 4-20mA (switch-selectable)
    Conversion Speed 15ms/channel (voltage), 30ms/channel (current)
    Isolation Non-isolated between channels
    Power Consumption 5V DC 90mA (internal supply)
    Accuracy ±1% (voltage), ±1% (current)
    Temperature Range 0-55°C (operating), -25-75°C (storage)
    Weight 0.2kg

    SEOQandA

    question:Why are the labels cut off on received products?
    answer:Labels are removed for inventory clearance or sample purposes. Functionality remains intact. Contact us for resolution.
    question:Do you accept payment after delivery?
    answer:Standard terms require prepayment. Flexible arrangements for trusted partners may apply. Discuss upfront for approval.
    question:Do you provide technical selection services?
    answer:Yes, our experts assist in product selection based on specifications. Contact support for tailored recommendations.

    SEOQandA_Product

    question:How to resolve unstable readings from FX3U-4AD?
    answer:Use shielded cables, ensure proper grounding, and avoid noise sources near the module.
    question:Why does FX3U-4AD show communication errors?
    answer:Check wiring integrity, verify module address settings, and confirm PLC compatibility.
    question:How to configure FX3U-4AD for voltage/current input?
    answer:Set BFM#0 parameters correctly: 0 for voltage, 1 for current (each channel via 4-digit HEX).
    question:Why is FX3U-4AD not detected by the PLC?
    answer:Verify module installation position, power supply (24VDC), and connector connections.
    question:How to fix incorrect scaling on FX3U-4AD?
    answer:Adjust BFM#5 range codes properly and ensure input matches selected range (e.g., 0-10V, 4-20mA).