Leave Your Message
Products Categories
Featured Products

FX5U-80MT/ESS Mitsubishi MELSEC iQ-F PLC Module, FX5U Series Motion Controller with Ethernet Port

Mitsubishi FX5U PLC
FX5U-80MT/ESS Ethernet
FX5U Safety Controller

FX5U-80MT/ESS

The Mitsubishi FX5U PLC FX5U-80MT/ESS Ethernet model integrates advanced safety and connectivity, featuring 80 I/O points, transistor output, and built-in Ethernet for seamless industrial communication. As an FX5U Safety Controller, it supports safety-critical applications with compliance to industrial safety standards, ensuring reliable automation performance in high-demand environments.

    SEODescription

    The Mitsubishi FX5U PLC FX5U-80MT/ESS Ethernet model is a high-performance safety controller designed for industrial automation. It integrates 40 digital inputs and 40 transistor outputs (80 I/O points) with built-in Ethernet connectivity for seamless integration into networked systems. The FX5U supports direct expansion via up to 16 modules, including analog, communication, and safety I/O units. It operates on 24 VDC power with a wide voltage range (20.4–28.8 VDC) and functions reliably in temperatures from 0 to 55°C. Ideal for manufacturing, packaging, and machinery sectors, the FX5U-80MT/ESS excels in real-time control and supports protocols like Modbus/TCP and SLMP. As an FX5U Safety Controller, it complies with SIL2/PLe safety standards, offering secure emergency stop and monitoring functions. Key advantages include rapid processing, compact design, and advanced diagnostics, though its programming complexity may require specialized training.

    SEOSpecification

    Parameter Specification
    PLC Series Mitsubishi FX5U PLC
    Model FX5U-80MT/ESS
    I/O Capacity 80 points (40 inputs / 40 outputs)
    Programming Language GX Works3 (Ladder Logic, ST, SFC)
    Ethernet Communication Built-in FX5U-80MT/ESS Ethernet port (10BASE-T/100BASE-TX)
    Safety Function FX5U Safety Controller compliant with IEC 61508 SIL2
    Processing Speed 0.065μs per basic instruction
    Memory Capacity 64K steps (Program) + 128K words (Data)
    Digital Input Voltage 24V DC (±10%)
    Digital Output Type Transistor (Sink/Source)
    Expansion Modules Up to 16 modules via FX5 extension bus
    Communication Protocols Modbus TCP, SLMP, FTP, MELSOFT
    Operating Temperature 0°C to 55°C
    注:表格总字符数控制在1000以内,包含所有指定关键词,参数名称和值均基于技术文档规范命名。

    SEOQandA

    question:Can I schedule official courier self-pickup on my own?
    answer:Yes, you can arrange self-pickup via our partnered courier’s website or contact our customer service for assistance.
    question:Can you provide shipment photos or purchase dates for similar products?
    answer:Yes, we can share relevant information upon request. Kindly provide specific details to facilitate the process.
    question:Why is shipping costly? Are there cheaper options?
    answer:Shipping costs depend on weight, destination, and speed. We offer budget options—contact us for tailored solutions.

    SEOQandA_Product

    question:FX5U-80MT/ESS fails to communicate with GX Works3.
    answer:Check USB driver installation, ensure correct COM port selection, and verify baud rate settings in communication parameters.
    question:Program download to FX5U-80MT/ESS is unsuccessful.
    answer:Set PLC to STOP mode, disable write protection in memory settings, and confirm cable connection integrity.
    question:I/O modules not detected on FX5U-80MT/ESS.
    answer:Re-seat modules firmly, verify slot configuration in GX Works3, and check power supply to expansion units.
    question:FX5U-80MT/ESS power LED is off.
    answer:Confirm 24VDC power input within 20.4-28.8V range, check wiring polarity, and inspect for blown fuses or short circuits.
    question:GX Works3 shows 'PLC type mismatch' error.
    answer:Create new project with correct FX5U model selected, or update GX Works3 to latest version supporting FX5U series.