Leave Your Message
Products Categories
Featured Products

Q68TD-G-H01 Thermo Couple Input Module, MELSEC-Q Series, Mitsubishi Electric PLC Temperature Detection Module

Q68TD-G-H01 Temperature Module
Q68TD-G-H01 8-Channel Input
Q68TD-G-H01 Thermocouple Module

Q68TD-G-H01

The Q68TD-G-H01 Temperature Module is an 8-channel input thermocouple module designed for precise temperature measurement, supporting multiple thermocouple types in industrial automation systems.

    SEODescription

    The **Q68TD-G-H01 Temperature Module** is an advanced 8-channel input module designed for precise temperature measurement in industrial automation. As a **Q68TD-G-H01 Thermocouple Module**, it directly connects to thermocouples (Type K, J, R, S, T, E, B, N) and supports high-accuracy temperature monitoring with a resolution of 0.1°C. Operating within a voltage range of 24 VDC ±10%, it integrates seamlessly with PLC systems via the MELSEC-Q series backplane, enabling real-time data acquisition. The **Q68TD-G-H01 8-Channel Input** configuration allows simultaneous monitoring of multiple processes, ideal for industries like chemical processing, energy, and manufacturing. It operates reliably in temperatures from 0°C to 55°C and features built-in noise resistance for stable performance in harsh environments. Key advantages include modular scalability and diagnostic functions, though its specialized thermocouple compatibility may limit flexibility with other sensor types.

    SEOSpecification

    Parameter Specification
    Model Q68TD-G-H01 Temperature Module
    Input Type Q68TD-G-H01 Thermocouple Module (K/J/T/E/R/S/B/N/C/W/Pt100/JPt100)
    Channels Q68TD-G-H01 8-Channel Input (Isolated)
    Resolution 16-bit (0.1°C unit)
    Temperature Range -200°C to 1300°C (Type-dependent)
    Accuracy ±0.1% of reading ±1°C
    Sampling Cycle 500ms/channel (All channels)
    Isolation Channel-to-channel: 500V AC
    Power Supply 5V DC ±5% (Backplane powered)

    SEOQandA

    question:Why choose your company for purchase?
    answer:We are Asia's leading industrial automation trader with 20+ years of experience, reliable quality, strong reputation, and 85% repeat customers.
    question:Received goods with removed labels. What happened?
    answer:Labels might be removed during transit or customs inspection. Contact us immediately for resolution.
    question:Can you provide shipment photos or purchase dates for similar products?
    answer:Yes, we share relevant documentation upon request to ensure transparency and build trust.

    SEOQandA_Product

    question:Q68TD-G-H01 not communicating with PLC.
    answer:Verify power supply, wiring, and communication settings in module parameters.
    question:Inaccurate temperature readings on Q68TD-G-H01.
    answer:Check sensor type configuration in parameters and ensure proper shielding/cabling.
    question:Channel status LED not lit on Q68TD-G-H01.
    answer:Confirm sensor connection, channel enable settings, and troubleshoot wiring faults.
    question:Q68TD-G-H01 shows 'Error' indicator.
    answer:Check error code via diagnostics, resolve wiring issues or configuration mismatches.
    question:Broken wire detection not triggering on Q68TD-G-H01.
    answer:Enable broken wire detection in parameters and verify threshold settings.