Original
- Siemens
- Allen-Bradley
- Schneider
- OMRON
- Keyence
- KEYENCE
- ABB
- MITSUBISHI
- YASKAWA
- Danfoss
- Hikvision (Light Source)
- HIKROBOT industrial computer
- Grating ruler
- MODULE+DRIVE
- Panasonic
- TP-LINK
- UOTKE
- MOWESTAR
- FINDER Price List
- KINCO
- RESI
- Weidmueller
-
Festo
- Festo VUVX
- Festo Solenoid valve VUVS
- Festo Solenoid valve VUVG
- Festo Standards-based valve VSVA
- Festo Solenoid valve VSNC
- Festo Solenoid valve VMPA
- Festo Push-in fitting QST
- Festo Push-in fitting QSL
- Festo Push-in fitting QS
- Festo Standard valve MFH
- Festo Standard valve JMFH
- Festo Standards-based cylinder DSBG
- Festo Round cylinder DSNU
- Festo cylinder DSBC
- Festo Compact cylinder ADN-S
- Festo Compact cylinder ADN
- Pneumatic Accessories
- AIRTAC
- SKF
- Traco
- PHOENIX
- EATON
- BECKHOFF
- Honeywell flame detector
- SMC
- IFM
- Yaskawa
- TRACO
- Patlite Industrial alarm light
- Series 55 - Miniature Power Relays 12
- Delta
- Autonics
- Semikron
- Bently Nevada
- Pepperl-fuchs
- Bosch TOOL
- LENZE
- SEW
- Mean Well
- Phoenix
- Patlite
- Honeywell
- MELSEC-F Series
- BECKHOFF
- smc
- IFM
- phoenix
-
Substitutes
- SIEMENS Substitutes
- Allen-Bradley Substitutes
- Mitsubishi Substitutes
- OMRON Substitutes
- GE FANUC Substitutes
- KEYENCE Substitutes
- Delta Substitutes
- Panasonic Substitutes
- Yaskawa Substitutes
- Koyo Substitutes
- Schneider Substitutes
- Hitachi Substitutes
- VIGOR Substitutes
- Hakko Substitutes
- HITECH Substitutes
- Weintek Substitutes
- Proface Substitutes
- MCGS Substitutes
- Kinco Substitutes
- IDEC Substitutes
- Fuji Substitutes
- Emerson Substitutes
- T-VERTER Substitutes
- Compatible with PLC and its boards
- Delta DOP.DVP Series PLC
- Freflex link cable
- HaiWell PLC Programming Cable
- Inovance IT7070 7100 Touch Screen Connected To Mitsubishi FX PLC
- Kinco Touch Screen With PLC
- Mitsubishi FX.Q Series PLC
- Omron PLC With Weilun Touch Screen
- Panasonic PLC And Weilun Touch Screen Communication Line
- Siemens S7-200/300 Series PLC
- Xinjie XC/XD Series PLC
- MINGWEI Substitutes
-
PLC CABLE
- Xinjie XC/XD Series PLC
- Delta DOP.DVP Series PLC
- HaiWell PLC Programming Cable
- Inovance IT7070 7100 Touch Screen Connected To Mitsubishi FX PLC
- Kinco Touch Screen With PLC
- Mitsubishi FX.Q Series PLC
- Omron PLC With Weilun Touch Screen
- Panasonic PLC And Weilun Touch Screen Communication Line
- Siemens S7-200/300 Series PLC
-
MRO
- Diy-More Circuit Board
- KELU, NCT electronic components
- Schaffner、BAOYILAI、XTOOL、XTOOL
- Switching power supply, UPS power supply, linear power supply, power and energy
- Photoelectric sensor
- Electric tool
- Relay
- Electronic components
- LCM LCD module
- Industrial fans
- Grating ruler
- Sensors
- Belimo sensor
- Industrial fan
- Sensor
-
IC Brands
-
ADI
- Voltage Translators, Level Shifters
- Voltage Reference
- Temperature Sensors - Analog and Digital Output
- Supervisors
- Signal Switchess, Multiplexers, Decoders
- RF Switches
- RF Mixers
- RF Amplifiers
- Microphones
- Linear Voltage Regulators
- Instrumentation Amplifier
- Digital to Analog Converters (DAC)
- Digital Potentiometers
- Analog to Digital Converters (ADC)
- Analog Multipliers, Dividers
- Altera
- Analog Devices
- Atmel
- Avago
- CJ
- Cypress
- Diodes
- Fairchild
- IMP
- Infineon
- Integrated Circuit Chip
-
Intersil
- Voltage Supervisors
- Voltage Reference
- Video Amps and Modules
- Sensor and Detector Interfaces
- RF Transistors (BJT)
- Power Management IC
- PMIC - Power Supply Controllers, Monitors
- Optical Sensors - Ambient Light, IR, UV Sensors
- Multiplexers and Demultiplexers
- Linear Regulator
- Interface - Drivers, Receivers, Transceivers
- Integrated Circuits (ICs) - PMIC - Voltage Regulators - Special Purpose
- Instrumentation Amplifier
- IC Chips
- Hot Swap Controllers
- Gate Drivers
- Digital Potentiometers
- DC Switching Regulators
- Comparators
- Battery Management System
- AC DC Converters, Offline Switchers
- ISOCOM
- JST
- Linear Technology
-
Maxim
- Voltage Reference
- Thermostats - Solid State
- Supervisors
- RF Amplifiers
- Linear Voltage Regulators
- LED Drivers
- Interface - Drivers, Receivers, Transceivers
- Instrumentation Amplifier1
- Hot Swap Controllers
- DC Switching Regulators
- Battery Management
- Analog to Digital Converters (ADC)
- Analog Switches, Multiplexers, Demultiplexers
- Microchip
- Micron
- Microne
- MPS
- NS(National Semiconductor)
- NXP(Nexperia)
-
ON(ON Semiconductor)
- Zener Diodes - Single
- Voltage Reference1
- TVS Diodes
- Triacs
- Transistors (BJT) - Single
- Supervisors1
- Specialized Power Management IC
- SCRs
- Power Distribution Switches, Load Drivers
- Motor Drivers and Controllers
- Linear Voltage Regulators
- IGBTs - Single
- Diodes, Rectifiers - Single
- DC Switching Regulators1
- Current Regulation/Management
- Clock Generators and Frequency Synthesizers
- AC DC Converters, Offline Switchers
- Realtek
-
RENESAS
- Triacs
- Transistor Output Optocouplers
- Telecom Interface ICs
- Supervisors1
- Solid State Relays
- SCRs
- RF Transistors (BJT)
- RF Switches
- Microcontrollers
- Logic Output Optocouplers
- LED Drivers
- Interface - Drivers, Receivers, Transceivers
- Gate Drivers
- FETs - Single
- FETs - Arrays
- Digital Potentiometers
- Clock Generators and Frequency Synthesizers
- ADCs/DACs
- Richtek
- ROHM
- SAMSUNG
- Sinopower
- STM
-
TOSHIBA
- Zener Diodes - Single
- Variable Capacitance Diodes (Varicaps, Varactors)
- TVS Diodes
- Transistors (BJT) - Single
- Transistor Output Optocouplers
- Special Purpose Transistors
- Solid State Relays
- Schottky Diodes
- RF Diodes
- Oscillators
- Non-Rechargeable Batteries
- Multivibrators
- Motor Drivers and Controllers
- Linear Regulator
- Linear ICs ; Operational Amplifiers and Comparators
- Gates and Inverters
- FETs - Single
- Diodes, Rectifiers - Single
- DC Switching Regulators
- Battery Holders, Clips, Contacts
- VISHAY
- Winbond
- Xilinx
- Fuse
- ALPHA & OMEGA
-
ADI
- Instrumentation
- C-ClIN
- Limit switch
- FOTEK
- Sensor
- Connecting cables
- KSS
- FANGNUO
- NUOMI
- CONTINENTAL
- SHHAPQ
- DE SHENG
- SIPU
- BULL
- E-Weichat
- WNE
- HongSH
- CHCC
- LJ
- LZ
- KSR
- Waterproof Connector
- Shenler
- HGS
- Button
- DELIX
- Hao Xiang
- Zheng gong
- Li wei
- DIY-MORE
- GONEO
- SHANHAO-kj
- LUOTAI
- Domenzi
- Medium load mold spring
- RF connector
- Electrical connector
- 304 Stainless steel rivet nut
- Big head carriage bolt
- Expansion Hoop Stainless Steel Elevator
- Stainless steel special hole opener
- Thick iron plate hole opener
- SHANG GONG Milling cutter
- Smart camera
- Smart lamps
- 304 Stainless steel cylindrical locating pin
- 70 Degree tungsten steel 4-edge milling cutter
- 4-Edge 55 degree hard tungsten steel alloy milling cutter
- SIYOUFAN
- VELLEDQ
- Pizzato Limit switch
- SUZST
- LAIZE
- RESI
- FLUKE
- Hexagonal shank multi-tooth flat wing drill
- OMCH
- Wood splitter
- Woodworking deep hole drill
- Qing liang Micrometer
- CHNT pilot lamp
- LQFR
-
Smart Home
- Smart Camera
- Smart lamps
- Smart cat litter box
- WiFi pet feeder
- Smart socket
- Smart power strip
- Sweeping robot
- WiFi water leak detector alarm
- WiFi temperature and humidity detector
- WiFi infrared detector
- WiFi emergency button/alarm siren
- Smart switch
- WiFi door/window magnetic detector
- Smart doorbell
- Smart door lock
- Portable label machine
- Intelligent alarm (smoke, carbon monoxide)
- TBI
- HIWIN
- PMI
- THK
- GEYA
- YanSeng
- KaiLan
- Plug & Socket
- ZJYIE
- Photovoltaic panel
- Aligning bearings
- Spherical Bearings
- 2-edge 65-degree carbide tungsten steel ball end milling cutter
- Tools Accessories
- Garden Tools
- Hand Tools
- Tool Box
- TA8315C,TA862A
- RR
- ROGY
- XURUI
- GP precision guide rails and guide bushes
- TOOLS
- Switching machine
- UOTEK
- MOWESTAR
- DELTA
- Products
- EtherCAT Terminals
- Connectivity for all common fieldbus systems
- AB
- plug-in modules
- IO-EtherCAT BOX EPPxxxx
- PLC adapter
01
RJ71GP21-SX MELSEC iQ-R GP21-SX CPU Module Mitsubishi Electric PLC Controller
Mitsubishi RJ71GP21-SX module
RJ71GP21-SX CPU module
Redundant RJ71GP21-SX controller
SEODescription
The Mitsubishi RJ71GP21-SX module is a high-performance redundant CPU module designed for mission-critical industrial automation systems. As part of the MELSEC iQ-R series, this Redundant RJ71GP21-SX controller supports seamless dual-CPU synchronization, ensuring uninterrupted operation in industries like power generation, chemical processing, and manufacturing. It features 32 digital inputs and 32 digital outputs directly onboard, with expansion capabilities for up to 64 additional modules via high-speed backplane connectivity. The module supports multiple communication protocols including Ethernet, CC-Link IE Field, and serial interfaces, enabling integration with diverse industrial networks. Operating within a 24 VDC ±10% voltage range and a temperature tolerance of 0–55°C, it excels in harsh environments. Key advantages include millisecond-level redundancy switching, real-time diagnostics, and modular scalability, though its complexity requires specialized programming expertise, and the redundant architecture increases initial deployment costs compared to standard controllers.
SEOSpecification
| Parameter | Specification |
|---|---|
| Product Model | Mitsubishi RJ71GP21-SX module |
| Module Type | RJ71GP21-SX CPU module with redundancy |
| Redundancy Function | Dual CPU architecture for Redundant RJ71GP21-SX controller |
| Processing Speed | 0.9 ns/instruction (base performance) |
| Memory Capacity | 512 KB program memory, 1 MB data memory |
| Communication Interface | Built-in Ethernet (100BASE-TX/10BASE-T) ports |
| Redundancy Sync Method | Optical fiber cable connection (SX specification) |
| Hot Standby Switch Time | ≤ 50 ms (system recovery time) |
| Power Supply | DC 24V ±10% (5.0A max) |
| Operating Temperature | 0°C to 55°C (32°F to 131°F) |
SEOQandA
question:Why can't you supply discontinued models that others can?
answer:Some suppliers may use remaining stock or refurbished parts, but we prioritize quality and reliability by offering current models only.
question:Why do other suppliers have discontinued items you can't provide?
answer:Suppliers might source from old inventory or unauthorized channels, whereas we adhere to ethical practices and updated product lines.
question:Can shipments apply for low-value declaration?
answer:Low-value declarations depend on destination regulations; we comply legally but cannot guarantee eligibility for all shipments.
answer:Some suppliers may use remaining stock or refurbished parts, but we prioritize quality and reliability by offering current models only.
question:Why do other suppliers have discontinued items you can't provide?
answer:Suppliers might source from old inventory or unauthorized channels, whereas we adhere to ethical practices and updated product lines.
question:Can shipments apply for low-value declaration?
answer:Low-value declarations depend on destination regulations; we comply legally but cannot guarantee eligibility for all shipments.
SEOQandA_Product
question:How to resolve communication errors with RJ71GP21-SX?
answer:Check physical connections, verify network settings, and ensure all nodes have unique station numbers.
question:Why does RJ71GP21-SX fail to initialize?
answer:Confirm power supply stability, validate parameter settings, and reset the module if necessary.
question:How to troubleshoot slow data transmission?
answer:Optimize network topology, reduce node count per segment, and check for electromagnetic interference.
question:What causes 'Station Number Duplication' errors?
answer:Ensure each device on the CC-Link IE Field network has a unique station number configured.
question:How to recover from firmware update failure?
answer:Reapply the firmware using a stable power source and ensure compatibility with the hardware version.
answer:Check physical connections, verify network settings, and ensure all nodes have unique station numbers.
question:Why does RJ71GP21-SX fail to initialize?
answer:Confirm power supply stability, validate parameter settings, and reset the module if necessary.
question:How to troubleshoot slow data transmission?
answer:Optimize network topology, reduce node count per segment, and check for electromagnetic interference.
question:What causes 'Station Number Duplication' errors?
answer:Ensure each device on the CC-Link IE Field network has a unique station number configured.
question:How to recover from firmware update failure?
answer:Reapply the firmware using a stable power source and ensure compatibility with the hardware version.