Leave Your Message
Products Categories
Featured Products

Sensix SX-D4800-E1FA4 D4000 Series Drive Module Motor Controller E1FA4 Industrial Driver

SX-D4800-E1FA4
D4800-E1-Controller
E1FA4-Module

SX-D4800-E1FA4

SX-D4800-E1FA4 industrial automation solution features the D4800-E1-Controller core and expandable E1FA4-Module, enabling reliable signal processing, real-time monitoring, and seamless integration in communication systems and industrial control applications.

    SEODescription

    The SX-D4800-E1FA4 is an industrial control system integrating the D4800-E1-Controller and E1FA4-Module, designed for high-performance automation. It features 16 digital inputs, 8 relay outputs, and supports direct connection to up to 4 expansion modules for scalability. Equipped with Ethernet, RS-485, and CAN interfaces, it ensures versatile communication in complex networks. Operating at 24V DC (±10%) and tolerating temperatures from -20°C to 60°C, it suits harsh environments in manufacturing, energy, and process industries. The modular design enhances flexibility, while robust construction ensures reliability. However, its advanced configuration may require specialized expertise, and initial costs are higher than basic controllers. The E1FA4-Module excels in real-time data processing, making the system ideal for precision-driven applications.

    SEOSpecification

    Parameter Specification
    Model Code SX-D4800-E1FA4
    Core Controller D4800-E1-Controller with dual ARM Cortex-A72 processors
    Interface Module E1FA4-Module supporting 4x E1 ports (G.703/G.704 compliant)
    Data Rate 2.048 Mbps per E1 channel ±50ppm
    Frame Structure Unframed/PCM30/PCM31 configurable
    Timing Mode Internal clock/Network timing/Loop timing
    Power Supply DC 48V (36-72V range) with dual redundant inputs
    Operating Temp -40°C to +75°C (industrial grade)
    Alarm Monitoring LOS, AIS, LOF, CV detection per ITU-T G.732
    Management SNMP v3/CLI/Web GUI via D4800-E1-Controller

    SEOQandA

    question:What is the warranty?
    answer:The warranty covers defects in materials or workmanship for a specified period from purchase date.
    question:Can the company provide upgraded or alternative models?
    answer:Yes, we offer upgraded or compatible alternatives based on availability and market requirements.
    question:How is refurbished product failure handled post-sale?
    answer:We investigate thoroughly, terminate supplier partnerships if confirmed, and compensate affected clients.

    SEOQandA_Product

    question:SX-D4800-E1FA4 fails to establish E1 link. How to resolve?
    answer:Check physical connections, verify line coding/clock settings match both ends, and test with loopback diagnostics.
    question:SX-D4800-E1FA4 shows high packet loss. What steps to take?
    answer:Inspect cabling for damage, verify impedance matching, and monitor for electromagnetic interference sources nearby.
    question:How to reset SX-D4800-E1FA4 to factory defaults?
    answer:Press recessed reset button for 15 seconds using a paperclip while powered on, then reboot.
    question:SX-D4800-E1FA4 firmware update fails. Solution?
    answer:Ensure correct firmware version, verify checksum, disable firewall temporarily, and use wired management port.
    question:SX-D4800-E1FA4 not responding to management interface. Fix?
    answer:Verify IP configuration, test with crossover cable, check ACL settings, and try alternative management port.